Configuration Portal
The configuration portal is a small captive-portal-style web page served from the miner itself while it is in AP mode.
When the portal is shown
- First boot after flashing.
- Reconnect failure — if the miner cannot reach the saved WiFi within ~15 seconds it falls back to AP mode automatically.
- Manual force — long-press the configure-button (see Buttons).
Reaching it
- Open WiFi settings on your phone or laptop.
- Join the open hotspot
nmap-2.4g. - On a phone, a captive-portal browser pops up automatically. On a PC, open
http://192.168.4.1.
You will see the configuration form described in First Configuration.
Save behaviour
Pressing Save writes the new settings, waits for the on-device storage to flush (10-15 s) and then reboots. Do not power-cycle during this window — let it restart on its own.